

- Inno Setup Install Ftdi Driver full#
- Inno Setup Install Ftdi Driver code#
- Inno Setup Install Ftdi Driver windows#

Inno Setup Install Ftdi Driver windows#
Note, however, that this is not an Inno Setup-specific limitation Windows Installer-based installers cannot return to the original user credentials either in such cases.

The same is true if Setup is launched from an already-elevated process.
Inno Setup Install Ftdi Driver code#
If a user launches Setup by right-clicking its EXE file and selecting "Run as administrator", then this flag, unfortunately, will have no effect, because Setup has no opportunity to run any code with the original user credentials. This is the default behavior when the postinstall flag is used. If this flag is specified and the system is running Windows Vista or later, the spawned process will execute with the (normally non-elevated) credentials of the user that started Setup initially (i.e., the "pre-UAC dialog" credentials). This flag cannot be combined with the runasoriginaluser flag. This is the default behavior when the postinstall flag is not used.
Inno Setup Install Ftdi Driver full#
If this flag is specified, the spawned process will inherit Setup/Uninstall's user credentials (typically, full administrative privileges). This generated entry runs the README file and has flags shellexec, skipifdoesntexist, postinstall and skipifsilent. If the compiler detects a entry with an isreadme flag, it strips the isreadme flag from the entry and inserts a generated entry at the head of the list of entries. The isreadme flag for entries in the section is now obsolete. If Setup has to restart the user's computer (as a result of installing a file with the flag restartreplace or if the AlwaysRestart section directive is yes), there will not be an opportunity for the checkbox to be displayed and therefore the entry will never be processed. Previously this flag was called showcheckbox. The user can uncheck or check this checkbox and thereby choose whether this entry should be processed or not. Instructs Setup to create a checkbox on the Setup Completed wizard page. Cannot be combined with waituntilidle or waituntilterminated. If this flag is specified, it will not wait for the process to finish executing before proceeding to the next entry, or completing Setup. If this flag is specified, the wizard will be hidden while the program is running. This flag cannot be combined with the shellexec flag. On an installation supporting both 32- and 64-bit architectures, it is possible to avoid the error by adding a Check: IsWin64 parameter, which will cause the entry to be silently skipped when running on 32-bit Windows. This flag can only be used when Setup is running on 64-bit Windows, otherwise an error will occur. This is the default behavior in a 64-bit mode install. įilename: " constant to map to the 64-bit System directory when used in the Filename and WorkingDir parameters. The following is an example of a section. If you don't want this, set the RestartIfNeededByRun directive to no. Note that by default, if a program executed in the section queues files to be replaced on the next reboot (by calling MoveFileEx or by modifying wininit.ini), Setup will detect this and prompt the user to restart the computer at the end of installation. By default, when processing a / entry, Setup/Uninstall will wait until the program has terminated before proceeding to the next one, unless the nowait, shellexec, or waituntilidle flags are used. Programs are executed in the order they appear in the script. Both sections share an identical syntax, except where otherwise noted below. The section is optional as well, and specifies any number of programs to execute as the first step of uninstallation. The section is optional, and specifies any number of programs to execute after the program has been successfully installed, but before the Setup program displays the final dialog.
